Stryker 988, 3CCD / Ref: 988-010-000

The Stryker Endoscopy Model 988 Medical Video Camera is designed for all types of video endoscopy applications. The Model 988 camera, with the proper coupler, can be used with most endoscopes or arthroscopes. Stryker Endoscopy’s line of focusing camera couplers maximizes the surgeon’s television viewing area for various endoscope sizes and applications. The light sensitivity and color reproduction of the Stryker Endoscopy system produces excellent picture quality.

A Stryker Endoscopy Model 988 Medical Video Camera consists of a camera head, a coupler, a camera control unit, and associated cables. These can be purchased together or separately. Stryker Endoscopy considers instructional training, or in-service, as an integral part of the Model 988 Medical Video Camera. Your local Stryker Endoscopy sales representative will perform at least one in-service at your convenience to help you set-up your equipment and instruct you and your staff on its operation and maintenance. Please contact your local Stryker Endoscopy representative to schedule an in-service after your equipment has arrived.

Imaging System

 1/3” Interline Transfer, EX view HAD CCD 768 (H) x 494 (V) pixels

Scanning System 2:1 Interlaced

Horizontal: 15.734 kHz

Vertical: 59.94 Hz

Video Outputs

Composite:         One NTSC standard                                             Digital:        Two Digital Video Interface (DVI)

                            1.0V P-P into 75 Ohms                                                              1024X768 XGA resolution

Connector:         BNC coaxial                                                          Connector:   29-pin DVI-I

Component:      Two S-VHS                                                             Digital:          One Serial Digital Interface (SDI)

                             Y-1.0V P-P C-0.29V P-P                                                              SMPTE-259M

Connector:        4-Pin S-VHS                                                            Connector:   BNC Coaxial

Resolution

Horizontal:         950 lines

Vertical:              500 lines

Signal to Noise Ratio          72 dB

Mounting                     Endoscope Eyepiece used with coupler

                                      C-mount camera head used with C-mount scopes

                                      (C-mount 1”-32UN-2A)

Minimum Illumination      < 1.0 Lux

Auto Shutter Range            1/60 to 1/50,000 second

Gain

      OFF 0 dB

       LOW 5 dB

       MEDIUM 10 dB

       HIGH 15 dB

Operating Temperature       5° to 40°

Transport & Storage

              Temperature               5° to 40° C

             Relative Humidity        10% to 85%

            Atmospheric Pressure 700 hPa to 1060 hPa

Power Consumption                approx. 30 W

Input Voltage Range                100/120 VAC 50/60 Hz

Total Shipping Weight             13 lbs (5.9 kg)

Dimensions

Camera Control Unit: 9.8”w x 4.0”h x 15”d (24.8cm w X 10.1cm h X 38.1cm d)

Camera Head Cable to Camera Control Unit: 10 foot (3m) sealed cable or 21.3 foot (6.5m) sealed cable (sensed by CCU)

Enhancement                                Switchable to 8 steps

Classification & Approvals           Complies with IEC 601-1 with Amendments 1 & 2, CSA Std. c22.2 No. 601.1 – M90, and UL Std. No. 2601-1

                                                       Complies with EN 60601-1-2: 1993 (EMC compliance of medical devices)

                                                      Type BF applied part or Type CF applied part as labeled on the product

                                                      Class I equipment

                                                      Ordinary equipment

                                                      Continuous operation

 